Promega Corporation

PowerPlex® Y23 System

The PowerPlex® Y23 System is a 23-loci, 5-color Y-STR multiplex designed for genotyping forensic casework samples, database samples and paternity samples. The kit contains: all 12 loci in the current PowerPlex® Y System, the additional 5 loci found in AmpFlSTR® Y-filer®, plus 6 new loci.

The PowerPlex® Y23 System works well with extracted DNA samples, including low amounts of template and male/female DNA mixtures. The PowerPlex® Y23 System also is compatible with direct amplification, enabling streamlined Y-STR databasing efforts. Amplification can be successfully performed with sample types s...

Expand to Read More »

  • Share
  • Print
  • Email
  • Prices valid for customers of Promega France only
Product Size Conc. Catalog # *List Price Order QTY Add to Cart
PowerPlex® Y23 System
Close Window

PowerPlex® Y23 System  Components

  • 2800M Control DNA

    DD710A1 x 25μl
  • PowerPlex® Y23 5X Master Mix

    DP108A1 x 250μl
  • Water, Amplification Grade

    DW099A1 x 1,250μl
  • PowerPlex® Y23 Allelic Ladder Mix

    DG248B1 x 25μl
  • CC5 Internal Lane Standard 500 Y23

    DG380A1 x 300μl
  • PowerPlex® Y23 10X Primer Pair Mix

    DK209B1 x 125μl
Close Window
  • This product can be added to a

  • Helix Freezer

This product is available through the Promega Helix onsite stocking program in a –20°C Helix Freezer. The program offers numerous convenient solutions to meet your lab's needs. Helix Freezers are available in two sizes: 5.7 cubic ft. or 9.7 cubic ft.


Click here to learn more about the Helix Collection »


Already a Helix Customer?

Request to add this product to your Helix »


50 reactions
- DC2305 € 1 784,00 Add to cart
PowerPlex® Y23 System
Close Window

PowerPlex® Y23 System  Components

  • 2800M Control DNA

    DD710A1 x 25μl
  • Water, Amplification Grade

    DW099A5 x 1,250μl
  • PowerPlex® Y23 Allelic Ladder Mix

    DG248B4 x 25μl
  • CC5 Internal Lane Standard 500 Y23

    DG380A2 x 300μl
  • PowerPlex® Y23 10X Primer Pair Mix

    DK209B4 x 125μl
  • PowerPlex® Y23 5X Master Mix

    DP108A4 x 250μl
Close Window
  • This product can be added to a

  • Helix Freezer

This product is available through the Promega Helix onsite stocking program in a –20°C Helix Freezer. The program offers numerous convenient solutions to meet your lab's needs. Helix Freezers are available in two sizes: 5.7 cubic ft. or 9.7 cubic ft.


Click here to learn more about the Helix Collection »


Already a Helix Customer?

Request to add this product to your Helix »


200 reactions
- DC2320 € 6 381,00 Add to cart


Available Separately

PRODUCT SIZE CONC CATALOG # *List Price ORDER QTY. Add to Cart

CC5 Internal Lane Standard 500 Y23

Close Window

CC5 Internal Lane Standard 500 Y23

 Components

  • CC5 Internal Lane Standard 500 Y23

    DG380A1 x 300μl
300μl
- DG3801 € 408,00 Add to cart

2800M Control DNA

Close Window

2800M Control DNA

 Components

  • 2800M Control DNA

    DD710A1 x 25μl
25μl
10ng/μl DD7101 € 90,00 Add to cart

2800M Control DNA

Close Window

2800M Control DNA

 Components

  • 2800M Control DNA

    DD725A1 x 500μl
500μl
0.25ng/μl DD7251 € 66,00 Add to cart

Water, Amplification Grade

Close Window

Water, Amplification Grade

 Components

  • Water, Amplification Grade

    DW099A5 x 1,250μl
Close Window
  • This product can be added to a

  • Helix Cabinet, Freezer, Refrigerator

This product is available through the Promega Helix onsite stocking program in a room temperature cabinet, a –20°C Helix Freezer or a +4°C Helix Refrigerator. The program offers numerous convenient solutions to meet your lab's needs.


Click here to learn more about the Helix Collection »


Already a Helix Customer?

Request to add this product to your Helix »


6,250μl
(5 × 1,250μl)
- DW0991 € 26,00 Add to cart

You Also May Be Interested In

Storage Conditions

Upon receipt of kit, remove 2800M Control DNA and store at 4°C. Store all other kit components at –20°C.

For product intended use please see Patents & Disclaimers tab.

10436MA_1000pxFigure 1. The PowerPlex® Y23 System allows co-amplification and four-color detection of 23 male-specific STR loci: DYS576, DYS389I/II, DYS448, DYS19, DYS391, DYS481, DYS549, DYS533, DYS438, DYS437, DYS570, DYS635, DYS390, DYS439, DYS392, DYS643, DYS393, DYS458, DYS385 a/b, DYS456 and YGATA-H4.

/~/media/images/resources/figures/10400-10499/10436ma_1000px.jpg?la=fr-FR
10476TA_550pxFigure 2. Amplification of one 1.2mm Bode Buccal DNA Collector™ punch preprocessed with prototype PunchSolution™ Reagent using 26 cycles with the PowerPlex® Y23 System.

Amplified products were separated on an Applied Biosystems 3130xl Genetic Analyzer (3kV, 5 second injection).

Amplified products were separated on an Applied Biosystems 3130xl Genetic Analyzer (3kV, 5 second injection).

/~/media/images/resources/figures/10400-10499/10476ta_550px.jpg?la=fr-FR
10653TA_975pxFigure 3. Amplification of 62.5pg of male DNA in the presence of 400ng of female DNA using 30 cycles and the PowerPlex® Y23 System.

Amplified products were separated on an Applied Biosystems® 3130 Genetic Analyzer (3kV, 5-second injection).

Amplified products were separated on an Applied Biosystems® 3130 Genetic Analyzer (3kV, 5-second injection).

/~/media/images/resources/figures/10600-10699/10653ta_975px.jpg?la=fr-FR
10433MA_800pxFigure 4. Amplification of two 1.2mm punches from buccal sample on an FTA® card using 27 cycles with the PowerPlex® Y23 System.

Amplified products were separated on an Applied Biosystems 3130xl Genetic Analzyer (3kV, 5-second injection).

Amplified products were separated on an Applied Biosystems 3130xl Genetic Analzyer (3kV, 5-second injection).

/~/media/images/resources/figures/10400-10499/10433ma_800px.jpg?la=fr-FR

Use Restrictions

DC2305, DC2320, DG3801, DD7101, DD7251, DW0991 Not For Medical Diagnostic Use.

Patents - Disclaimers

DC2305, DC2320 U.S. Pat. No. 6,242,235, Australian Pat. No. 761757, Canadian Pat. No. 2,335,153 and other patents and patents pending.

DC2305, DC2320 This product or portions thereof is manufactured and sold under license from GE Healthcare under Australia Pat. No. 692230, Austria Pat. No. E236994, Belgium Pat. No. 0743987, Canada Pat. No. 2231475, EP Pat. Nos. 0743987 and 0851867, France Pat. Nos. 0743987 and 0851867, Germany Pat. Nos. 19581489, 69530286.8 and 0851867, Italy Pat. Nos. 0743987 and 0851867, Japan Pat. No. 3066984, Liechtenstein Pat. Nos. 0743987 and 0851867, Netherlands Pat. Nos. 0743987 and 0851867, Spain Pat. Nos. 2197193 and 2173310, Sweden Pat. Nos. 0743987 and 0851867, Switzerland Pat. Nos. 0743987 and 0851867, United Kingdom Pat. Nos. 0743987 and 0851867, U.S. Pat. Nos. 5,654,419, 5,688,648, 5,869,255, 6,177,247, 5,707,804, 6,028,190, 6,544,744, 7,015,000 and 5,728,528 and other pending and foreign patent applications.

End User Terms and Conditions

Acceptance. These terms and conditions shall govern the purchase, use, transfer and acceptance of the products described in the purchase order, quotation or invoice, which products are sold and distributed by Promega to the buyer/transferee of such products (the "End User"). The transfer/sale of products to the End User is expressly conditional upon End User's acceptance of these terms and conditions.

Restrictions on Use. End Users are specifically not authorized to and are forbidden from reselling, transferring or distributing any products either as a stand alone product or as a component of another product. The right to use the products does not, in and of itself, include or carry any right of the End User to any GE Healthcare Bio-Sciences Corp.'s technology or intellectual property other than expressly provided herein. End Users may not use sequence(s) in an attempt to reverse engineer parameters of any of GE Healthcare Bio-Sciences Corp. proprietary products or services.

Disclaimer of Warranties. GE Healthcare Bio-Sciences Corp. provides no warranties to end user (statutory or implied), including without limitation, as to product quality, condition, description, merchantability or fitness for a particular purpose, and all such warranties are hereby expressly disclaimed. GE Healthcare Bio-Sciences Corp. hereby expressly disclaims any warranty regarding results obtained through the use of the products, including without limitation any claim of inaccurate, invalid or incomplete results.

Exclusion of Liability. GE Healthcare Bio-Sciences Corp. and its affiliates shall have no liability to an End User, including, without limitation, for any loss of use or profits, business interruption or any consequential, incidental, special or other indirect damages of any kind, regardless of how caused and regardless of whether an action in contract, tort, strict product liability or otherwise.

DC2305, DC2320 TMR-ET, CXR-ET and CC5 dyes are proprietary.

DC2305, DC2320 STR loci are the subject of U.S. Pat. No. RE 37,984, German Pat. No. DE 38 34 636 C2 and other patents issued to the Max-Planck-Gesellschaft zur Förderung der Wissenschaften, e.V., Germany.

Prefer a different language?

Your country is set to France. Your language is set to français. Please select the language that will best suit your needs:

This is correct, continue to site »

I need additional help

It appears that you have Javascript disabled. Our website requires Javascript to function correctly. For the best browsing experience, please enable Javascript.