The CellTiter-Blue® Cell Viability Assay provides a homogeneous, fluorescent method for monitoring cell viability. The assay is based on the ability of living cells to convert a redox dye (resazurin) into a fluorescent end product (resorufin). Nonviable cells rapidly lose metabolic capacity and thus do not generate a fluorescent signal. The homogeneous assay procedure involves adding the single reagent directly to cells cultured in serum-supplemented medium. After an incubation step, data are recorded using either a plate-reading fluorometer (preferred) or spectrophotometer.
The homogeneous, add-incubate-measure format of the assay reduces the number of handling steps. The assay has an excellent Z´ factor and offers more flexibility in assay incubation times compared to other resazurin-based assays.
The reagent is generally nontoxic to cells, allowing extended incubation periods in some situations and requires no scintillation cocktail, radioactive waste disposal (unlike [3H]-thymidine incorporation assays) or hazardous solvents (as required for MTT tetrazolium-based assays). It is designed to provide sufficient volumes for accurate pipetting into 96- or 384-well formats, and convenient product sizes are available for high-throughput screening.
Notes
Each G8080 system provides sufficient reagents to perform 1,000 assays in a 96-well format or 4,000 assays in a 384-well format when the recommended volumes are used. Likewise, each G8081 system provides sufficient reagents to perform 5,000 and 20,000 assays; each G8082 system provides sufficient reagents to perform 50,000 and 200,000 assays.
Protocols
Specifications
Catalog Number:
What's in the box
| Item | Part # | Size |
|---|---|---|
|
CellTiter-Blue® Reagent |
G808A | 1 × 20ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
What's in the box
| Item | Part # | Size |
|---|---|---|
|
CellTiter-Blue® Reagent |
G808B | 1 × 100ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
What's in the box
| Item | Part # | Size |
|---|---|---|
|
CellTiter-Blue® Cell Viability Assay |
G8081 | 10 × 100ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
Resources
No related resources available
Related Products
Similar Products
RealTime-Glo™ MT Cell Viability Assay
A bioluminescent method to kinetically monitor viability in cell culture up to 72 hours.
G9711, G9712, G9713
CellTiter-Glo® 2.0 Cell Viability Assay
Updated CellTiter-Glo® Cell Viability Assay with improved reagent stability. Quantifies cell proliferation based on ATP detection.
G9241, G9242, G9243
CellTiter-Glo® 3D Cell Viability Assay
A homogeneous method optimized to assess viability in 3D cell culture.
G9681, G9682, G9683
CellTiter-Fluor™ Cell Viability Assay
A non-lytic, single-reagent-addition fluorescence assay that measures the relative number of viable cells in a population.
G6080, G6081, G6082
Frequently Used With
LDH-Glo™ Cytotoxicity Assay
Bioluminescence-based LDH assay for sensitive detection of cytotoxicity in samples low in cell number, including 3D microtissues.
J2380, J2381
Apo-ONE Homogeneous Caspase-3/7 Assay
A complete assay for the fast and sensitive measurement of active caspase-3 and -7.
G7792, G7790, G7791
Caspase-Glo® 3/7 Assay System
An easy-to-use, plate-based luminescent assay for detecting caspase-3/7 activity.
G8090, G8091, G8093, G8092
RealTime-Glo™ Apoptosis and Necrosis Assay
A one-step, plate-based assay for continually monitoring apoptosis progression.
JA1011, JA1012, JA1000, JA1001